Air Tightness and Thermal Imaging testing are important quality control measures when building or renovating a house. 35% of heatloss comes from air leakage through chimneys, attics, wall vents and badly sealed windows/doors etc,. |
|
Air tightness can be tested with a door blower fan to identify areas experiencing heat loss through leakage. A fan is put on the door and the house is pressurised and de-pressurised to 50kp to check for leakage. We have achieved good results by lining the inside of the roofs with 9mm OSB with the joints taped or a Vapour Control layer. Sealing around service pipes and windows/doors improves results. Chimneys can be stuffed with a bin bag filled with Rockwool or a special balloon. |
![]() |
A Thermal imaging camera identifies patterns of heat loss that are invisible to the naked eye. It is quite difficult to identify small air gaps using building air tightness testing alone. Air tightness testing and thermal imaging complement each other and their combined use quickly indicate air leaks within a property.
This Image shows a Dublin roof on a calm day
|
|
|
This image shows the same roof on a windy day. This clearly proves that we need to address Wind tightness in the next round of the building regulations. On windy nights the U-value is blown out of the insulation in most Irish roofs. Our calculations show that the U-value of this roof dropped from 0.25 to 0.65 when the wind started blowing which is every second day in Ireland. We usually line our roofs with Softboard to make them breathable and windthight.
Significant savings on annual heating bills can be realised by carrying out Airtightness work. Air infiltrates into and out of dwellings via many routes. The rate of infiltration depends upon the airtightness of the dwelling and the driving forces of wind and temperature. Excessive infiltration wastes heat and causes draughts, which can be a major source of discomfort. The ventilation required in a home is better provided by purpose-designed openings, over which occupants have some control, rather than by incidental leakage where there is no control. Full airtightening work should not be undertaken without providing controllable ventilation.
|
In this image you can see where the |
This image shows where the |

Passive Slab is Passive House certified to deliver the lowest U-value (as low as 0.08W/m.K) on the market and eliminates the critical wall-floor Cold Bridge. Read More
Cellulose insulation is made from recycled wood fibre, primarily newspaper. One hundred kilos of cellulose insulation contains 80 to 85 kilos of recycled newsprint. Waste disposal is a major problem for cities. Cellulose unquestionably meets all requirements for insulation specified by the guideline. Read More
ICF Insulated Concrete Forms are formwork for concrete that stay in place as permanent building insulation for energy-efficient, cast-in-place, reinforced concrete walls, floors, and roofs. The forms are interlocking modular units that are dry-stacked (without mortar) and filled with concrete. The forms lock together somewhat like Lego bricks and serve to create a form for the structural walls or floors of a building. Read More
Our Timber frame Passive Houses usually arrive on site pre-finished with Cellulose Insulation in the walls and triple glazed Passive House windows fitted. The Timber frame walls can be pre-finished internally, so no wet trades are required on site.Read More
Passive Houses are highly insulated, comfortable, cold bridge free structures that require little heating, they usually have triple glazed windows, heat recovery ventilation (HRV) and high air-tightness levels. It doesn’t cost extra to build a Passive House using our construction methods, as money saved on a complex heating system pays for better windows or extra insulation. Read More